TUBING INSPECTION
Tubing Inspection Service
Heat exchanger tubing inspection using IRIS, ECT, RFT, and NFT — matched to tubing material and inspection objective.
Overview
What we deliver
Doctorndt provides full-coverage tubing inspection for heat exchangers, condensers, and similar tube bundle equipment. Method selection is matched to tubing material, defect mechanism, and the data the integrity team needs.
Inspections detect wall loss, pitting, cracking, and tube support degradation. Results are reported with clear severity grading and tube maps that support repair and re-tube planning.
Applications
- Refineries
- Petrochemical plants
- Power generation
- Air-cooled heat exchangers
- Condensers and reboilers
- Probes Rentals
- Manpower Supply
- Tube Inspection Training
- Online Data Analysis
Tubular Inspection Methods
EDDY CURRENT TESTING
Fastest electromagnetic technique for non-ferrous tubing — evaluates ID and OD in one pass and distinguishes ID/OD-originating defects.
REMOTE FIELD TESTING
Remote Field Testing — fastest, most cost-effective method for ferrous tubing, evaluating ID and OD in a single pass.
NEAR FIELD TESTING
Near Field Testing for aluminum-finned ferrous tubing such as fin-fans and air coolers.
IRIS TESTING
Internal Rotary Inspection System — quantitative remaining wall thickness to ±0.003″, used to confirm ET/RFT/NFT findings.
BENEFITS
- Detection of wall loss, pitting, and cracking
- Identification of tube support degradation
- Method matched to tube material and defect mechanism
- Clear tube maps and severity grading for repair planning
TALK TO DOCTORNDT
Ready to scope your next inspection?
Tell us about your facility, scope, and schedule. An DOCTORNDT inspection specialist will follow up to discuss methods, mobilization, and reporting.